Re-Factored CR6 Community Touchscreen Firmware - Release Candidate 61F_RC_090522_v2
PLEASE READ THE README FILE BEFORE FLASHING THIS FIRMWARE TO YOUR PRINTER.
Flashing the DWIN_SET in this release installs a TouchScreen that works with the CF6.1-Final motherboard firmware and runs on any version of DGUS2 (v2.0 or higher.)
If you have DGUS2 v4.5 flashed to your display, you should flash this DWIN_SET instead of the one bundled with the motherboard firmware.
If you already have the CR6Community Firmware running on DGUS2 v3.5 on your printer, then you do not need to flash this firmware.
NOTE: The Load screen and the Setup->Info page will confirm the release number you have flashed, which should match the release number in the filename and in the README.MD file.
NEW AT THIS RELEASE:
There are three Thermal Error screens in the current design.
If any one of those conditions is triggered, it may not be clear whether the problem is with the Nozzle or the Bed.
Hoping to provide important troubleshooting clues, we have added Nozzle and Bed Sensor and Target readouts to all three of these thermal error screens:
- Thermistor Error
- Thermal Runaway
- Heating Failed
While making these edits, we were also made aware (by InsanityAutomation) of a problem with the Z-Offset buttons implemented on the Printing Tune menu, which caused problems when held down rather than being tapped. We have implemented the fix that he recommended, in this release.
Other miscellaneous edits made at this release are:
- Nudged the temperature value displays to a common and suitable spacing on all screens.
- Replaced the two-part zip files of the new DGUSTool with a single consolidated file.
- Added a folder of Sample Screen Images, to help guide and inform users of this firmware
- Stopped using the build.ps1 script to build the DWIN_SET. Noticed that it renames files 13 and 14 from what names the new tool is giving them. Speculating (but have not yet confirmed by testing) that the white noise screen at the end of flashing to DGUS2 v4.5 screens may be a condition aggravated by those filenames having been changed.
We have designated this DWIN_SET as 61F_RC_090522_v2.