-
Notifications
You must be signed in to change notification settings - Fork 559
/
Copy pathdriver.go
165 lines (131 loc) · 4.89 KB
/
driver.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
/*
Copyright 2018 The Ceph-CSI Authors.
Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS,
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
See the License for the specific language governing permissions and
limitations under the License.
*/
package cephfs
import (
"k8s.io/klog"
csicommon "github.com/ceph/ceph-csi/pkg/csi-common"
"github.com/ceph/ceph-csi/pkg/util"
"github.com/container-storage-interface/spec/lib/go/csi"
)
const (
// volIDVersion is the version number of volume ID encoding scheme
volIDVersion uint16 = 1
// csiConfigFile is the location of the CSI config file
csiConfigFile = "/etc/ceph-csi-config/config.json"
// RADOS namespace to store CSI specific objects and keys
radosNamespace = "csi"
)
// PluginFolder defines the location of ceph plugin
var PluginFolder = ""
// Driver contains the default identity,node and controller struct
type Driver struct {
cd *csicommon.CSIDriver
is *IdentityServer
ns *NodeServer
cs *ControllerServer
}
var (
// CSIInstanceID is the instance ID that is unique to an instance of CSI, used when sharing
// ceph clusters across CSI instances, to differentiate omap names per CSI instance
CSIInstanceID = "default"
// volJournal is used to maintain RADOS based journals for CO generated
// VolumeName to backing CephFS subvolumes
volJournal *util.CSIJournal
)
// NewDriver returns new ceph driver
func NewDriver() *Driver {
return &Driver{}
}
// NewIdentityServer initialize a identity server for ceph CSI driver
func NewIdentityServer(d *csicommon.CSIDriver) *IdentityServer {
return &IdentityServer{
DefaultIdentityServer: csicommon.NewDefaultIdentityServer(d),
}
}
// NewControllerServer initialize a controller server for ceph CSI driver
func NewControllerServer(d *csicommon.CSIDriver, cachePersister util.CachePersister) *ControllerServer {
return &ControllerServer{
DefaultControllerServer: csicommon.NewDefaultControllerServer(d),
MetadataStore: cachePersister,
VolumeLocks: util.NewVolumeLocks(),
}
}
// NewNodeServer initialize a node server for ceph CSI driver.
func NewNodeServer(d *csicommon.CSIDriver, t string) *NodeServer {
return &NodeServer{
DefaultNodeServer: csicommon.NewDefaultNodeServer(d, t),
VolumeLocks: util.NewVolumeLocks(),
}
}
// Run start a non-blocking grpc controller,node and identityserver for
// ceph CSI driver which can serve multiple parallel requests
func (fs *Driver) Run(conf *util.Config, cachePersister util.CachePersister) {
// Configuration
PluginFolder = conf.PluginPath
if err := loadAvailableMounters(conf); err != nil {
klog.Fatalf("cephfs: failed to load ceph mounters: %v", err)
}
if err := util.WriteCephConfig(); err != nil {
klog.Fatalf("failed to write ceph configuration file: %v", err)
}
// Use passed in instance ID, if provided for omap suffix naming
if conf.InstanceID != "" {
CSIInstanceID = conf.InstanceID
}
// Get an instance of the volume journal
volJournal = util.NewCSIVolumeJournal()
// Update keys with CSI instance suffix
volJournal.SetCSIDirectorySuffix(CSIInstanceID)
// Update namespace for storing keys into a specific namespace on RADOS, in the CephFS
// metadata pool
volJournal.SetNamespace(radosNamespace)
initVolumeMountCache(conf.DriverName, conf.MountCacheDir)
if conf.MountCacheDir != "" {
if err := remountCachedVolumes(); err != nil {
klog.Warningf("failed to remount cached volumes: %v", err)
// ignore remount fail
}
}
// Initialize default library driver
fs.cd = csicommon.NewCSIDriver(conf.DriverName, util.DriverVersion, conf.NodeID)
if fs.cd == nil {
klog.Fatalln("failed to initialize CSI driver")
}
if conf.IsControllerServer || !conf.IsNodeServer {
fs.cd.AddControllerServiceCapabilities([]csi.ControllerServiceCapability_RPC_Type{
csi.ControllerServiceCapability_RPC_CREATE_DELETE_VOLUME,
csi.ControllerServiceCapability_RPC_EXPAND_VOLUME,
})
fs.cd.AddVolumeCapabilityAccessModes([]csi.VolumeCapability_AccessMode_Mode{
csi.VolumeCapability_AccessMode_MULTI_NODE_MULTI_WRITER,
})
}
// Create gRPC servers
fs.is = NewIdentityServer(fs.cd)
if conf.IsNodeServer {
fs.ns = NewNodeServer(fs.cd, conf.Vtype)
}
if conf.IsControllerServer {
fs.cs = NewControllerServer(fs.cd, cachePersister)
}
if !conf.IsControllerServer && !conf.IsNodeServer {
fs.ns = NewNodeServer(fs.cd, conf.Vtype)
fs.cs = NewControllerServer(fs.cd, cachePersister)
}
server := csicommon.NewNonBlockingGRPCServer()
server.Start(conf.Endpoint, conf.HistogramOption, fs.is, fs.cs, fs.ns, conf.EnableGRPCMetrics)
if conf.EnableGRPCMetrics {
go util.StartMetricsServer(conf)
}
server.Wait()
}